|
|
| | Author: | SezaR | Posted: | Oct 31, 2021 16:40 | Subject: | Inventory Change Request for Set 9605-2 | Viewed: | 19 times | Topic: | Inventories Requests (Entry) | Status: | Open | |
|
| Please make changes to the following inventory:
* Delete 3 Part 766c92 Light Gray Electric, Wire 12V / 4.5V with two 2-prong connectors, 92 Studs Long (Alternate) (match ID 3)
* Add 3 Part 766c96 Light Gray Electric, Wire 12V / 4.5V with 2 Leads, 96 Studs Long with 2 Light Gray Electric, Connector, 2-Way Male Squared Narrow Long with Center Post (x466c96 / 766c01) (Alternate) (match ID 3)
* Delete 3 Part 766c23 Light Gray Electric, Wire 12V / 4.5V with two 2-prong connectors, 23 Studs Long
* Add 3 Part 766c28 Light Gray Electric, Wire 12V / 4.5V with 2 Leads, 28 Studs (22cm) Long with 2 Light Gray Electric, Connector, 2-Way Male Squared Narrow Long with Center Post
Comments from Submitter:
Just parted-out this set. These wires added by axaday are the same as those I request to add to this set.
For example, the length of wire alone for 766c23 is about 18-19cm. I compare it with 766c28 from my personal collection and they are almost of the same length. As a note, the length of wires were never that exact. I have tested wires of 5 copies of 7722 from my personal collection and the length of wires of max length and min length were about 2cm different.
|
|
|
| | | | | |
| | | | Author: | TakeAbricK | Posted: | May 2, 2022 04:12 | Subject: | Re: Inventory Change Request for Set 9605-2 | Viewed: | 24 times | Topic: | Inventories Requests | |
|
| In Inventories Requests, SezaR writes:
| Please make changes to the following inventory:
* Delete 3 Part 766c92 Light Gray Electric, Wire 12V / 4.5V with two 2-prong connectors, 92 Studs Long (Alternate) (match ID 3)
* Add 3 Part 766c96 Light Gray Electric, Wire 12V / 4.5V with 2 Leads, 96 Studs Long with 2 Light Gray Electric, Connector, 2-Way Male Squared Narrow Long with Center Post (x466c96 / 766c01) (Alternate) (match ID 3)
* Delete 3 Part 766c23 Light Gray Electric, Wire 12V / 4.5V with two 2-prong connectors, 23 Studs Long
* Add 3 Part 766c28 Light Gray Electric, Wire 12V / 4.5V with 2 Leads, 28 Studs (22cm) Long with 2 Light Gray Electric, Connector, 2-Way Male Squared Narrow Long with Center Post
Comments from Submitter:
Just parted-out this set. These wires added by axaday are the same as those I request to add to this set.
For example, the length of wire alone for 766c23 is about 18-19cm. I compare it with 766c28 from my personal collection and they are almost of the same length. As a note, the length of wires were never that exact. I have tested wires of 5 copies of 7722 from my personal collection and the length of wires of max length and min length were about 2cm different.
|
You want to change a 23 studs wire to a 28 studs wire, saying that your wire
is (also) about 18-19 cm. But 28 studs is 22.4 cm and 23 studs is 18.4 cm
You say the difference between minimum and maximum length is about 2cm.
Which means:
- a 22.4 cm wire (28 studs) can be 21.4 - 23.4 cm
- a 18.4 cm wire (23 studs) can be 17.4 - 19.4 cm
Personally I think a difference of 1cm either way, is already a big difference.
Could you please check all 3 wires in your set 9605-2 and measure the
length of the complete wire in centimeters (so including the pieces that
are in the connectors)?
Reading also the other post of this set, you are saying your wires in set 9605-2
are
you say almost about 18-19 cm
Thanks,
Diana
|
|
|
| | | | | | | | | |
| | | | | | Author: | axaday | Posted: | May 2, 2022 06:04 | Subject: | Re: Inventory Change Request for Set 9605-2 | Viewed: | 21 times | Topic: | Inventories Requests | |
|
| In Inventories Requests, TakeAbricK writes:
(so including the pieces that
Reza, if you are going to destroy one can you post here how much wire is inside
the connector?
|
|
| | | | | | | | | |
| | | | | | Author: | TakeAbricK | Posted: | May 14, 2022 04:21 | Subject: | Re: Inventory Change Request for Set 9605-2 | Viewed: | 22 times | Topic: | Inventories Requests | |
|
| In Inventories Requests, TakeAbricK writes:
| In Inventories Requests, SezaR writes:
| Please make changes to the following inventory:
* Delete 3 Part 766c92 Light Gray Electric, Wire 12V / 4.5V with two 2-prong connectors, 92 Studs Long (Alternate) (match ID 3)
* Add 3 Part 766c96 Light Gray Electric, Wire 12V / 4.5V with 2 Leads, 96 Studs Long with 2 Light Gray Electric, Connector, 2-Way Male Squared Narrow Long with Center Post (x466c96 / 766c01) (Alternate) (match ID 3)
* Delete 3 Part 766c23 Light Gray Electric, Wire 12V / 4.5V with two 2-prong connectors, 23 Studs Long
* Add 3 Part 766c28 Light Gray Electric, Wire 12V / 4.5V with 2 Leads, 28 Studs (22cm) Long with 2 Light Gray Electric, Connector, 2-Way Male Squared Narrow Long with Center Post
Comments from Submitter:
Just parted-out this set. These wires added by axaday are the same as those I request to add to this set.
For example, the length of wire alone for 766c23 is about 18-19cm. I compare it with 766c28 from my personal collection and they are almost of the same length. As a note, the length of wires were never that exact. I have tested wires of 5 copies of 7722 from my personal collection and the length of wires of max length and min length were about 2cm different.
|
You want to change a 23 studs wire to a 28 studs wire, saying that your wire
is (also) about 18-19 cm. But 28 studs is 22.4 cm and 23 studs is 18.4 cm
You say the difference between minimum and maximum length is about 2cm.
Which means:
- a 22.4 cm wire (28 studs) can be 21.4 - 23.4 cm
- a 18.4 cm wire (23 studs) can be 17.4 - 19.4 cm
Personally I think a difference of 1cm either way, is already a big difference.
Could you please check all 3 wires in your set 9605-2 and measure the
length of the complete wire in centimeters (so including the pieces that
are in the connectors)?
Reading also the other post of this set, you are saying your wires in set 9605-2
are
you say almost about 18-19 cm
Thanks,
Diana
|
The 3 wires above and the 3 wires in the inventory are:
- duplicates of each other, or
- alternates of each other, or
- the inventory is correct as it is
Either way, this request can not be approved.
I did my best to determine if these 3 are all duplicates, by messaging both submitters.
So far I only received the length of 1 wire out of six during 2 weeks.
If we want all electric wires in the catalog to be correct, we really need information
about the length of these wires in centimeters. We also need to know if this
length is of the total wire (including piece of wire in connectors) or if
it's measured from connector to connector (length between connectors).
Diana
|
|
|
|
|
|